Table of Common Errors

The following table lists commonly encountered errors, a description of

the error, and possible solutions to eliminate the error. A complete

listing of errors may be found in the Reference Guide Appendix A -

Error

List.

Number Displayed Error Description Solution

Message

10000 The allowable The value entered in the Enter device

response was Allowable field in the specific values

unrecognized: Response Options for allowable

(Duration/Input Property response.

Page) is not recognized by

the input mask.

10001 The allowable The Allowable field in Enter device

response Response Options specific values

cannot be (Duration/Input Property for allowable

empty Page) must contain a value response.

when input is enabled.

10002 Cannot have A single value has been Verify that unique

duplicate entered more than the entries are

response Allowable field in the entered only once

Response Options

(Duration/Input Property

Page) represents a mask of

values, entering

duplicate values would be

redundant.

10017 Invalid The value entered in the Enter device

Termination Termination Response specific value for

Response field in the Advanced the termination

Response Options response

(Duration/Input Property

Page) is not recognized by

the input mask.

10018 Correct The value entered in the Specify a value

Response is Correct Response field in that is included as

not part of the Response Options part of the

Allowable (Duration/Input Property Allowable

Page) is not included as Response.

10019

10044

10046

18005

part of the Allowable

Response Options

Termination The value entered in the

Response is Termination Response

not part of field in the Advanced

Allowable Response Options

(Duration/Input Property

Page) is not included as

part of the Allowable

Response Options

The name An object was named in the

cannot be interface with a length of

longer than 80 more than 80 characters.

characters! An object name can only

contain A-Z, a-z, 0-9,

must begin with an

alphabetic character,

must not contain more than

80 characters, and must be

unique within the system

Name contains An object was named in the

an invalid interface with a value

character that contains an invalid

character. E-Object names

are generated to E-Basic

script, which does not

permit variable names to

have invalid characters.

An object name can only

contain A-Z, a-z, 0-9

Cannot load An error occurred while

sound file attempting to load a sound

. file. This can be due to

file not found, file

already open, lack of

resources, invalid

configuration, or

improper driver.

Specify a value

that is included as

part of the

Allowable Response

Enter a valid name

through the

Properties window,

Procedure time

line, or Structure

view windows that

does not have more

than 80

characters.

18010

Enter a valid name

through the

Properties window,

Procedure

timeline, or

Structure view

window that does

not have any

invalid

characters.

Ensure that the

configuration of

the file matches

the configuration

of the sound

device, that the

file is not already

open, and that the

filename and path

are valid

The value for The MaxLength field of the Set the value of

MaxLength is Sound object (General MaxLength to a

invalid property page) represents value no less than

a value that is not valid. 100.

18011 The value for

BitsPerSample

is invalid

18012 The value for

Channels is

invalid

18013 The value for

SamplesPerSec

ond is invalid

Valid values for MaxLength

cannot be less than 100

The BitsPerSample field of

the Sound device

(Experiment Object;

Devices tab) represents a

value that is not valid.

Common values are 8 and 16,

but the settings are

hardware dependent.

The Channels field of the

Sound device (Experiment

Object; Devices tab)

represents a value that is

not valid. Valid values

are 1 for mono and 2 for

stereo.

The SamplePerSecond field

of the Sound device

(Experiment Object;

Devices tab) represents a

value that is not valid.

Common values are 11025,

22050,

44100, but settings are

hardware dependent.

Set the value of

BitsPerSample to 8

or 16 to match the

format of the WAV

file. All files

must be saved using

the same format.

Set the value of

Channels to 1 or 2

to match the format

of the WAV file.

All files must be

saved using the

same format

Set the value of

SamplesPerSecond

to 11025, 22050, or

44100 to match the

format of the WAV

file. All files

must be saved using

the same format