DEMO MANUAL DC2570A

LTM4678

Dual 25A or Single 50A µModule Regulator with

Digital Power System Management,1× LTM4678, 50A

DESCRIPTION

Demonstration circuit 2570A is a dual output, high effi-

ciency, high density, µModule

®

regulator with 4.5V to 16V

input range. The output voltage is adjustable from 0.5V

to 33V and it can supply 50A maximum load current. The

demo board has a LTM

®

4678 µModule regulator, which is

a dual 25A or single 50A step-down regulator with digital

power system management. Please see LTM4678 data

sheet for more detailed information.

DC2570A powers up to default settings and produces

power based on configuration resistors without the

need for any serial bus communication. This allows

easy evaluation of the DC/DC converter. To fully explore

the extensive power system management features of the

part, download the GUI software LTpowerPlay

®

onto your

PC and use Analog Devices’ I

2

C/SMBus/PMBus dongle

DC1613A to connect to the board. LTpowerPlay allows

the user to reconfigure the part on-the-fly and store the

configuration in EEPROM, view telemetry of voltage, cur-

rent, temperature and fault status.

GUI Download

The software can be downloaded from: LTpowerPlay

For more details and instructions of LTpowerPlay, please

refer to LTpowerPlay GUI for LTM4678 Quick Start Guide.

Design files for this circuit board are available.

All registered trademarks and trademarks are the property of their respective owners.

Figure 1. Single-Output 50A LTM4678/DC2570A Demo Circuit

1

Rev. 0

DEMO MANUAL DC2570A

PERFORMANCE SUMMARY

PARAMETER

Input Voltage Range

Output Voltage, V

OUT

Maximum Output Current, I

OUT

Typical Efficiency

Default Switching Frequency

V

IN

= 4.5V to 16V, I

OUT

= 0A to 50A

V

IN

= 4.5V to 16V, V

OUT

= 0.5V to 3.3V

V

IN

= 12V, V

OUT

= 1.0V, I

OUT

= 50A

Specifications are at T

A

= 25°C

CONDITIONSMIN

4.5

0.51.0

50

86

(See Figure 5)

500

TYPMAX

16

3.3

UNITS

V

V

A

%

kHz

QUICK START PROCEDURE

Table 1. LTM4678 Demo Boards for Up to 250A Point-of-Load Regulation

MAXIMUM OUTPUT CURRENT

25A

50A

100A

150A

200A

250A

NUMBER OF OUTPUTS

2

1

1

1

1

1

NUMBER OF LTM4676 µModule

REGULATORS ON THE BOARD

1

1

2

3

4

5

DEMO BOARD NUMBER

DC2552A

DC2570A

DC2638A-A

DC2638A-B

DC2638A-C

DC2638A-D

Demonstration circuit 2570A is easy to set up to evaluate

the performance of the LTM4678. Refer to Figure 2 for

the proper measurement equipment setup and follow the

procedure below.

1. With power off, connect the input power supply to V

IN

(4.5V to 16V) and GND (input return).

2. Connect the 1.0V output load between V

OUT

and GND

(initial load: no load).

3. Connect the DVMs to the input and output. Set default

jumper position: SW1: ON.

4. Turn on the input power supply and check for the

proper output voltages. V

OUT

should be 1.0V ±0.5%.

5. Once the proper output voltage is established, adjust the

load within the operating range and observe the output

voltage regulation, ripple voltage and other parameters.

6. Connect the dongle and control the output voltages

from the GUI. See LTpowerPlay GUI for the LTM4678

Quick Start Guide for details.

Note: When measuring the output or input voltage

ripple, do not use the long ground lead on the oscil-

loscope probe. See Figure 3 for the proper scope probe

technique. Short, stiff leads need to be soldered to

the (+) and (–) terminals of an output capacitor. The

probe’s ground ring needs to touch the (–) lead and

the probe tip needs to touch the (+) lead.

2

Rev. 0