The Piston-type Steam pressure reducing valve

Instruction manual

Configurations:

1

2

3

4

5

6

Lower cover

Body

7

8

Piston ring

Cylinder

Secondary valve spring

Upper bonnet

Secondary valve

Secondary valve seat

13

14

15

16

17

Diaphragm

Adjusting spring

Valve cap

Adjusting screw

Top cap

Main valve spring 9

Main valve seat

Main valve

Piston

10

11

12

Main performance and uses:

Y43H is principally used in steam pipe, it can reduce the inlet

pressure to a certain outlet pressure you need by adjusting the

1

spring, when the flow and the pressure of the inlet varies, the

outlet pressure can also remain within a certain range by the

strength of the medium itself, but the differential pressure of the

inlet and outlet must be equal or greater than 0.2MPa.

Technical parameter:

DN

(LB)

300

Pressure test (MPa) Pressure-adjust range (MPa)

export

pressure

Import

Shell test Seat test

pressure

7.5 5.5 2.5

Applicable

Temperature

export

deviation

0.5~1.6

≤±0.7 ≤250

Working principal:

When the pressure reducing valve leaves the factory, the

adjusting spring is in uncompressed state, the main valve disc and

secondary valve disc is in close position. When you want to use it,

you can turn the adjusting screw clockwise; this can compress the

adjusting spring, move the diaphragm down and then open the

secondary valve disc, the medium also enters above the main

valve seat through “a” hole to “b” hole, make the main valve

disc open and then enters under the diaphragm through “c” hole.

But when the downstream pressure is exceed the set pressure, the

medium moves the diaphragm up and compresses adjusting

2

spring, and then the secondary valve disc closes slowly, because

the flow reduces, the downstream pressure get a new balance, on

the other hand, when the downstream pressure is less than the set

pressure, the gap between the main valve disc and the main valve

seat increases and then the flow increases too and then make the

downstream pressure get a new balance.

Installation and maintenance:

1. Clean the valve and the pipe line and remove the dirt before

installation, at the same time the valve must be installed in

horizontal direction, bracket is needed when the valve

deadweight is heavy or vibration exists at the site.

2. While installing, make sure the flow direction and the

direction marked on valve body is consistent, and a bypass

pipe is usually required. When the valve size and the pipe

size differ, reducer should be adopted. The installing site

should have sufficient space for a convenient usage and

maintenance.

3. When the valve is put into use, the bypass globe valve must

be opened, remove the condensate and the water vapor

mixture in order to avoid the water hammer occurred by

opening the valve. If there is no unusual phenomenon

3

appears, you can turn the adjusting screw clockwise till

getting the outlet pressure we need, then lock the nut and

cover the top cap.

4. A filter must be installed before the pressure reducing valve

which prevents the impurities from getting into the valve.

5. There must be a straight pipe at least 600mm and 1000mm

seperately before and after the pressure reducing valve.

6. A water-vapor separator and a steam trap should be installed

before the pressure reducing valve, atfter which a steam trap

should also be installed.

7. Pressure reducing valve should be kept in a dry room, both of

which should be blocked with blind plates. Do not keep in

piles.

8. If the pressure reducing valve will be kept for a long time, we

must check it regularly, clean up the dirt and spread some

rust-proof oil on the movement part and the machined

surface.

9. If the outlet pressure is higher than the inlet pressure, we

must reset the pressure reducing valve as follows:

① Shut off the upstream isolating valve;

② Relief the downstream pressure;

③ Turn the adjusting screw counterclockwise, make it in a free

4

poisition.

④ Open the upstream isolating valve slowly till full open.

⑤ Turn the adjusting screw clockwise, the outlet pressure rises

slowly to the set value, then lock the adjusting screw.

⑥ If you adjust the pressure too high, you must readjust it from

step 1 to step 5 (adjust from low pressure to high pressure only)

Installation diagram:

1 2 3

reducing

valve

4

Globe

valve

5

Safety

valve

6

Bypass

pipe

filter pressure gauge Pressure

5


本文标签: 读音 作者